DTM30 POINT CELLS

The DTM30 has 30 cells, each of which can be used for either point control or detection indication. To control a point, we will use one cell.  In this example - CELL1.

To control and indicate the current direction of the point with LEDs, a DTM30 will use two groups of output from cell1,

            -           one from SKT2 - LED drivers     - LED1A and LED1B

            -           one from SKT5 - Push Button     - SW1A

The DTM30 would be programmed to use CELL1 as a Point Cell 

Note:  On LEDs - C=Cathode, A=Anode:  Anodes are common = green line

To detect the position of a loco, we would use a detection circuit – called sensor in DTM language. Here we will use CELL 1 only for driving one LED (LED1A) to show that a loco has arrived at that sensor location. The DTM30 would be programmed to use CELL1 as a Sensor Cell. The next sensor would be connected to Cell 2 in the same way from different SKT2  pins.

 

           

Viaduct DTM30 Wiring to Control Panel

     
        Point Push Buttons SKT 5             LEDs SKT 2      
                        Anode usually has a longer lead than the Cathode  
Cell #  Point # SKT # Pin # Point PB # Point # PB SW #  Cell  DCC   Cell #  Block # SKT # Pin # LED # LED #  LED #  Cell  DCC
        Pin 1 COM Pin 2   Setting Address           Cathode  Anode   Setting Address
1 1 5 1 1   SW1A Point     1   2 1 P1S   LED1A    
    5 2     SW1B           2 2 P1T   LED1B    
2 2 5 3 2   SW2A Point     2   2 3 P2S   LED2A    
    5 4     SW2B           2 4 P2T   LED2B    
    5 5   P1/2 COM             2 5   P1/2 COM      
3 3 5 6 3   SW3A Point     3   2 6 P3S   LED3A    
    5 7     SW3B           2 7 P3T   LED3B    
4 4 5 8 4   SW4A Point     4   2 8 P4S   LED4A    
    5 9     SW4B           2 9 P4T   LED4B    
    5 10   P3/4 COM             2 10   P3/4 COM      
5 5 5 11 5   SW5A Point     5   2 11 P5S   LED5A    
    5 12     SW5B           2 12 P5T   LED5B    
6 6 5 13 6   SW6A Point     6   2 13 P6S   LED6A    
    5 14     SW6B           2 14 P6T   LED6B    
    5 15   P5/6 COM             2 15   P5/6 COM      
7 7 5 16 7   SW7A Point     7   2 16 P7S   LED7A    
    5 17     SW7B           2 17 P7T   LED7B    
8 8 5 18 8   SW8A Point     8   2 18 P8S   LED8A    
    5 19     SW8B           2 19 P8T   LED8B    
    5 20   P7/8 COM             2 20   P7/8 COM      
9 9 5 21 9   SW9A Point     9   2 21 P9S   LED9A    
    5 22     SW9B           2 22 P9T   LED9B    
10 10 5 23 10   SW10A Point     10   2 23 P10S   LED10A    
    5 24     SW10B           2 24 P10T   LED10B    
    5 25   P9/10 COM             2 25   P9/10 COM      
    5 26 N/C               2 26 N/C        
                                     
           

Viaduct DTM30 Wiring to Control Panel

     
        Point Push Buttons SKT 6             LEDs SKT 3      
                        Anode usually has a longer lead than the Cathode  
Cell #  Point # SKT # Pin # Point # Point # PB SW #  Cell  DCC   Cell #  Block # SKT # Pin # LED # LED #  LED #  Cell  DCC
        Pin 1 COM Pin 2   Setting Address           Cathode Anode   Setting Address
11 11 6 1 11   SW11A Point     11   3 1 P11S   LED11A    
    6 2     SW11B           3 2 P11T   LED11B    
12 12 6 3 12   SW12A Point     12   3 3 P12S   LED12A    
    6 4     SW12B           3 4 P12T   LED12B    
    6 5   P11/12 COM             3 5   P11/12 COM      
13 13 6 6 13   SW13A Point     13   3 6 P13S   LED13A    
    6 7     SW13B           3 7 P13T   LED13B    
14 14 6 8 14   SW14A Point     14   3 8 P14S   LED14A    
    6 9     SW14B           3 9 P14T   LED14B    
    6 10   P13/14 COM             3 10   P13/14 COM      
15 6T 6 11 6T   SW15A Point     15   3 11 6T   LED15A    
    6 12     SW15B           3 12     LED15B    
16 4T 6 13 4T   SW16A Point     16   3 13 4T   LED16A    
    6 14     SW16B           3 14     LED16B    
    6 15   6T/4T COM             3 15   6T/4T COM      
17 SHT 6 16 SHT   SW17A Point     17   3 16 SHT   LED17A    
    6 17     SW17B           3 17     LED17B    
18 ESS 6 18 ESS   SW18A Point     18   3 18 ESS   LED18A    
    6 19     SW18B           3 19     LED18B    
    6 20   SHT/ESS COM             3 20   SHT/ESS COM      
19 EPO 6 21 EPO   SW19A Point     19   3 21 EPO   LED19A    
    6 22     SW19B           3 22     LED19B    
20   6 23     SW20A       20 B14 3 23 B14   LED20A Sensor  
    6 24     SW20B           3 24     LED20B    
    6 25   EPO COM             3 25   EPO/B14 COM      
    6 26 N/C               3 26 N/C        
  Note: Cells 15 to 19 are used for the Control Pushbuttons e.g. 6T = 6 train Schedule Start / Stop        
                                     
           

Viaduct DTM30 Wiring to Control Panel

     
    Point Push Buttons SKT7 - NOT USED           LEDs SKT 4      
                        Anode usually has a longer lead than the Cathode  
Cell #  Point # SKT # Pin # Point # PB Point # PB SW #  Cell  DCC   Cell #  Block # SKT # Pin # LED # LED #  LED #  Cell  DCC
        Pin 1 COM Pin 2   Setting Address           Cathode Anode   Setting Address
21   7 1     SW22A       21 B15 4 1 B15   LED22A Sensor  
    7 2     SW22B           4 2     LED22B    
22   7 3     SW22A       22 B16 4 3 B16   LED22A Sensor  
    7 4     SW22B           4 4     LED22B    
    7 5   21,22 COM             4 5   B15/16COM      
23   7 6     SW23A       23 B18 4 6 B18   LED23A Sensor  
    7 7     SW23B           4 7     LED23B    
24   7 8     SW24A       24 B19 4 8 B19   LED24A Sensor  
    7 9     SW24B           4 9     LED24B    
    7 10   23,24 COM             4 10   B18/19COM      
25   7 11     SW25A       25 B20 4 11 B20   LED25A Sensor  
    7 12     SW25B           4 12     LED25B    
26   7 13     SW26A       26 B21 4 13 B21   LED26A Sensor  
    7 14     SW26B           4 14     LED26B    
    7 15   25,26,COM             4 15   B20/21,COM      
27   7 16     SW27A       27 B22 4 16 B22   LED27A Sensor  
    7 17     SW27B           4 17     LED27B    
28   7 18     SW28A       28 B23 4 18 B23   LED28A Sensor  
    7 19     SW28B           4 19     LED28B    
    7 20   27,28 COM             4 20   B22/23 COM      
29   7 21     SW29A       29 B24 4 21 B24   LED29A Sensor  
    7 22     SW29B           4 22     LED29B    
30   7 23     SW30A       30   4 23     LED30A Sensor  
    7 24     SW30B           4 24     LED30B    
    7 25   29,30 COM             4 25   B24 COM      
    7 26 N/C               4 26 N/C